NOTE: For the diagnostic procedure, refer to DTC P0606. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P0606 CONTROL MODULE PROCESSOR 1. OUTLINE OF DIAGNOSIS Judge as NG when SUM value of ROM is outside the standard value. 2. EXECUTION CONDITION
Diagnosis with the initial routine. 3. GENERAL DRIVING CYCLE Perform the diagnosis as soon as the ignition switch is turned to ON. 4. DIAGNOSTIC METHOD Judge as NG if the criteria below are met.
Time Needed for Diagnosis: 32 time(s) - 16 ms Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs. |
Installation
1. Install the knock sensor to the cylinder block, and connect the connector to the knock sensor.NOTE:• Install the knock sensor connector so that the center of the connector is aligned with the extension line from the cylinder block rib (a).• Make sure that the knock sensor and its conn ...