1. CHECK FUSE 1. Remove the fuse and inspect visually. 2. If the fuse is blown out, replace the fuse. 2. CHECK RELAY 1. Check the resistance between relay terminals.
2. Replace the relay if the inspection result is not within the standard value. |
Inspection
1. CHECK THE MASS AIR FLOW SENSOR UNIT1. Connect the battery positive terminal to terminal No. 3 and the battery ground terminal to terminal No. 4, and connect the circuit tester positive terminal to terminal No. 5 and the circuit tester ground terminal to terminal No. 4.2. Check the voltage changes ...