1. Install the manifold absolute pressure sensor to the intake manifold assembly, and connect the connector to the manifold absolute pressure sensor.

NOTE:

Use new O-rings.

Tightening torque:

3.4 N·m (0.3 kgf-m, 2.5 ft-lb)

2. Connect the ground terminal to battery sensor. NOTE

Inspection
1. Check that the manifold absolute pressure sensor has no deformation, cracks or other damages.2. Connect dry-cell battery positive terminal to terminal No. 3 and dry-cell battery ground terminal to ...

Mass air flow and intake air temperature sensor
...

Other materials:

2.5 L models
1) Clip  Unsnap the two clips holding the air cleaner case (rear). Open the air cleaner case. Remove the air cleaner element CAUTION If the inside of the air cleaner case is extremely soiled (for example, by sand), contact a SUBARU dealer and ...