CAUTION: • Do not start the engine before charging refrigerant. • If the engine is started with no refrigerant charge, replace the compressor assembly. • If the evaporator has been replaced, add an appropriate amount of compressor oil to the compressor. Compressor Oil > ADJUSTMENT • When the evaporator has been replaced, always replace the packing for expansion valve with a new one and apply the compressor oil on it. • Make sure that the water seal packing on the cover attachment area is securely attached. • Replace the O-rings with new parts, and then apply compressor oil. • Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION 1. Install the evaporator sensor to the specified location. Evaporator Sensor > INSTALLATION 2. Install the expansion valve - cooling. Tightening torque: 5 N·m (0.5 kgf-m, 3.7 ft-lb) 3. Install the evaporator. 4. Attach the heater case lower. 5. Install the duct - foot assist. 6. Attach the heater core. 7. Install the heater and cooling unit assembly. Heater and Cooling Unit > INSTALLATION 8. Connect the ground terminal to battery sensor. NOTE |
Specification
1. HEATER SYSTEMItemSpecificationsConditionHeating capacity4.8 kW (4,127 kcal/h, 16,377 BTU/h) or more• Air flow control switch: FOOT• Temperature control dial: HI (MAX HOT)• Temperature difference between hot water and inlet air: 65°C (149°F)• Hot water flow ra ...