CAUTION: • Do not start the engine before charging refrigerant. • If the engine is started with no refrigerant charge, replace the compressor assembly. • Replace the gasket and O-rings with new parts, and then apply compressor oil. 1. Install the expansion valve - cooling. Tightening torque: 5 N·m (0.5 kgf-m, 3.7 ft-lb) 2. Install the hose - pressure suction and the pipe - evaporator cooling. Tightening torque: 7.5 N·m (0.8 kgf-m, 5.5 ft-lb) 3. Connect the ground terminal to battery sensor. NOTE 4. Charge refrigerant. Refrigerant Charging Procedure > PROCEDURE |
Dtc b1576 egi control module eeprom
DTC DETECTING CONDITION:• ECM malfunctioning• When the ROM in ECM was inaccessible during registration.TROUBLE SYMPTOM:Engine will not start.CAUTION:For replacement procedure of ECM, refer to “REGISTRATION MANUAL FOR IMMOBILIZER” provided as a separate volume.STEPCHECKYESNO1. ...