1. Measure height “A” from the ST upper face to the bearing end face using the ST.
2. Measure depth “B” from the converter case cover upper face to the bearing catch surface. 3. Using the ST, measure height “C” from the ST upper face to the converter case cover mating surface.
4. Using the following formula, calculate clearance “T” to select shims. Calculation formula: T mm = (A − 15) − ((C − 15) − B) [T in = (A − 0.591) − ((C − 0.591) − B)] T: Clearance A: Depth from the ST upper face to the bearing end surface B: Depth from the converter case cover upper face to the bearing catch surface C: Height from the ST upper face to the converter case cover mating surface 15 mm (0.591 in): Thickness of ST
|
Inspection
1. CHECK FUSE1. Remove the fuse and inspect visually.2. If the fuse is blown out, replace the fuse.2. CHECK RELAY1. Measure the resistance between relay terminals.Terminal No.Inspection conditionsStandardCircuit1 — 2Always1 M- or more1 — 2Apply battery voltage between terminals 4 and 3.Less than ...