1. Check that the main relay has no deformation, cracks or other damages. 2. Measure the resistance between main relay terminals.
3. Connect battery positive terminal to terminal No. 2 and battery ground terminal to terminal No. 4, and measure the resistance between the main relay terminals.
|
Assembly
1. Install the hub unit COMPL to the ST securely.Preparation tool:ST: HUB STAND (28099PA080)2. Using a press, press new bolts - hub until their seating surfaces contact the hub unit COMPL.NOTE:Use the 12 mm (0.47 in) dia. holes in the HUB STAND to prevent bolts from tilting.(1)Hub unit COMPL - front ...