CAUTION: Be sure to prevent water or oil from contacting the connector terminal of turbine speed sensor. If adhesion occurs, replace with a new part. 1. Install the turbine speed sensor. NOTE: • Use new O-rings. • Apply CVTF to the O-rings. Tightening torque: 7 N·m (0.7 kgf-m, 5.2 ft-lb) 2. Connect the harness connector. 3. Lower the vehicle. 4. Connect the ground terminal to battery sensor. NOTE |
Dtc b2271 ign relay control circuit
DTC DETECTING CONDITION:• When malfunction is detected in IG1 and IG2 drive circuits in the keyless access CM.• When malfunction is detected in IG hold circuit in the keyless access CM.TROUBLE SYMPTOM:Not all functions operate at IGN ON.CAUTION:For replacement procedure of keyless access ...