1. Disconnect the ground terminal from battery sensor. NOTE 2. Using the refrigerant recovery system, discharge refrigerant. Refrigerant Recovery Procedure > PROCEDURE 3. Disconnect the hose - pressure suction and the pipe - evaporator cooling. CAUTION: Seal the disconnected hose, pipe and engaging part of expansion valve with a plug or vinyl tape to prevent foreign matter from entering. (1) Disconnect the connector. (2) Detach the clips and bolts, and detach the hose - pressure suction and the pipe - evaporator cooling. 4. Remove the bolt, and remove the expansion valve - cooling. CAUTION: Seal the pipe and engaging part of expansion valve with a plug or vinyl tape to prevent foreign matter from entering. Preparation tool: Hexagon wrench: 4 mm (0.16 in) |
Adjustment
1. THRUST BEARING PRELOAD1. Select a suitable adjusting washer No. 1 so that dimension (H) will be zero in a visual check. Position the washer (20 - 31 - 4) and lock washer (20 - 31 - 2.3) and attach the lock nut (20 - 11).2. Install the lock nut with ST1, ST2 and ST3.NOTE:• Use new lock nuts ...