Subaru Legacy BN/BS (2015-2019) Service Manual: Subaru select monitor
Item NameContentsStandardNoteTrip CountTime stamp information, trip counter — — CountTime stamp information, original counter identification information — — Time CountTime stamp information, ...
• For detailed operation procedures, refer to “Application help”.• If the SRF CM cannot communicate with Subaru Select Monitor, perform “COMMUNICATION FOR INITIALIZING IM ...
Other materials:
Inspection
1. YAW RATE & LONGITUDINAL G AND LATERAL G SENSOR SIGNALSTEPCHECKYESNO1.CHECK YAW RATE & G SENSOR.1) Check the installation condition of the VDC control module & hydraulic control module (VDCCM&H/U).2) Using the Subaru Select Monitor, display «Data monitor».3) Read the output of «Yaw Rate Sensor ...