DTC DETECTING CONDITION: Immediately at fault recognition CAUTION: After servicing or replacing faulty parts, perform Clear Memory Mode Clear Memory Mode > OPERATION, and Inspection Mode Inspection Mode > PROCEDURE.
1. OUTLINE OF DIAGNOSIS Detect the malfunction of tumble generator valve motor function. Judge close fixing malfunction when the opening degree is small even after finishing the tumble generator valve open driving. 2. EXECUTION CONDITION
3. GENERAL DRIVING CYCLE Always perform the diagnosis continuously. 4. DIAGNOSTIC METHOD If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Time Needed for Diagnosis: 3000 ms Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs. |
Dtc p2008 tgv control circuit/open bank 1
Dtc p2006 tgv control stuck closed bank 1Dtc p0141 o2 sensor heater circuit bank 1 sensor 2
NOTE:Refer to DTC P0037 for diagnostic procedure. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P0037 A/F / O2 HEATER CONTROL CIRCUIT LOW BANK 1 SENSOR 21. OUTLINE OF DIAGNOSISDetect malfunction of the rear oxygen sensor heater.Judge as NG if it is determined that the rear oxygen se ...