CAUTION: • Subaru Select Monitor is required for reading DTC, performing diagnosis and reading current data. • Remove foreign matter (dust, water, oil, etc.) from the body integrated unit connector during removal and installation. • Registration of immobilizer may be needed after the replacement of control modules, etc. For detailed procedure, refer to the “REGISTRATION MANUAL FOR IMMOBILIZER” provided as a separate volume. NOTE: • To check harness for open or short circuits, shake the suspected trouble spot or connector. • Check List for Interview Check List for Interview
|
Dtc b1833 short in curtain shield airbag rh squib circuit (to +b)
DIAGNOSIS START CONDITION:Ignition voltage is 10 V to 16 V.DTC DETECTING CONDITION:Short circuit failure in power supply (shorted in main harness power supply, shorted in curtain airbag RH power supply, shorted in airbag CM internal circuit power supply)CAUTION:Before performing diagnosis, refer to ...