CAUTION: • Subaru Select Monitor is required for reading DTC, performing diagnosis and reading current data. • Remove foreign matter (dust, water, oil, etc.) from the body integrated unit connector during removal and installation. • Registration of immobilizer may be needed after the replacement of control modules, etc. For detailed procedure, refer to the “REGISTRATION MANUAL FOR IMMOBILIZER” provided as a separate volume. NOTE: • To check harness for open or short circuits, shake the suspected trouble spot or connector. • Check List for Interview Check List for Interview
|
Check list for interview checkDtc b1830 short in curtain airbag rh squib circuit
DIAGNOSIS START CONDITION:Ignition voltage is 10 V to 16 V.DTC DETECTING CONDITION:Shorted between +/− lines (shorted between main harness lines, shorted between curtain airbag RH lines, shorted between airbag CM internal lines)CAUTION:Before performing diagnosis, refer to “CAUTION&rdquo ...