1. Install the hub unit COMPL to the ST securely. Preparation tool: ST: HUB STAND (28099PA080) 2. Using a press, press new bolts - hub until their seating surfaces contact the hub unit COMPL. NOTE: Use the 12 mm (0.47 in) dia. holes in the HUB STAND to prevent bolts from tilting.
|
Removal
InstallationInspection
1. Check that the main relay has no deformation, cracks or other damages.2. Measure the resistance between main relay terminals.Terminal No.Standard1 and 31 M- or more2 and 480.55 — 98.45 - (when 20°C (68°F))3. Connect battery positive terminal to terminal No. 2 and battery ground te ...