1. ACCESS KEY BATTERY Measure the access key battery voltage. Preparation tool: Circuit tester NOTE: Complete the measurement within 5 seconds because the battery discharges during measurement.
Replace the battery if the inspection result is not within the standard value. (Use CR2032 V or equivalent.) |
Replacement
RemovalDtc b1802 short in driver's airbag (to ground)
DIAGNOSIS START CONDITION:Ignition voltage is 10 V to 16 V.DTC DETECTING CONDITION:GND short circuit failure (shorted to ground in main harness, shorted to ground in roll connector, shorted to ground in driver’s airbag, shorted to ground in airbag CM internal circuit)CAUTION:Before performing ...