CAUTION: • Do not start the engine before charging refrigerant. • If the engine is started with no refrigerant charge, replace the compressor assembly. • Replace O-rings and pipe clamps with new parts and install securely. • Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION 1. Install the blower motor unit assembly. 2. Install the heater and cooling unit assembly. Heater and Cooling Unit > INSTALLATION 3. Connect the ground terminal to battery sensor. NOTE |
RemovalPrecautions in trouble diagnosis and repair of electric parts
1. Always refer to “CAUTION” and “NOTE” of “General Description” in the same models service manual before starting the diagnostics and repair.2. Always refer to the cautions of each section when diagnosing and repairing each system and component.3. The battery cab ...