Honda Civic manuals

Subaru Legacy BN/BS (2015-2019) Service Manual: Installation

CAUTION:

Do not start the engine before charging refrigerant.

If the engine is started with no refrigerant charge, replace the compressor assembly.

Replace O-rings and pipe clamps with new parts and install securely.

Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION

1. Install the blower motor unit assembly.

2. Install the heater and cooling unit assembly. Heater and Cooling Unit > INSTALLATION

3. Connect the ground terminal to battery sensor. NOTE

Removal
CAUTION:• Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION• ...

Blower resistor (manual a c model)
...

Other materials:

Dtc b1571 reference code incompatibility (immobilizer cm to ecm)
1. EXCEPT FOR C0 AND C5 MODELSDIAGNOSIS START CONDITION:• Battery voltage is 10 V or more.• The remote engine starter was not used to start the engine.DTC DETECTING CONDITION:Reference code incompatibility between body integrated unit and ECMTROUBLE SYMPTOM:• Engine will not start. ...