1. ACTUATOR LINK 1. Visually check the operating range of the link, and remove the foreign matter if any. 2. Operate the FRESH/RECIRC switch, and check that the link operates normally. 3. If it does not operate normally as the result of inspection, perform a unit inspection of motor - actuator blower. 2. CHECK ACTUATOR 1. Check the actuator operation when battery voltage is applied between the connector terminals. CAUTION: Disconnect the battery immediately after the actuator stops operation. Otherwise, the motor may be damaged.
2. If it does not operate normally as the result of inspection, replace the motor - actuator blower. |