1. ACTUATOR LINK 1. Visually check the operating range of the link, and remove the foreign matter if any. 2. Operate the FRESH/RECIRC switch, and check that the link operates normally. 3. If it does not operate normally as the result of inspection, perform a unit inspection of motor - actuator blower. 2. CHECK ACTUATOR 1. Check the actuator operation when battery voltage is applied between the connector terminals. CAUTION: Disconnect the battery immediately after the actuator stops operation. Otherwise, the motor may be damaged.
2. If it does not operate normally as the result of inspection, replace the motor - actuator blower. |
Removal
InstallationDtc u0423 invalid data received from instrument panel cluster control module
NOTE:Refer to “LAN SYSTEM (DIAGNOSTICS)” for diagnostic procedure. Basic Diagnostic Procedure1. OUTLINE OF DIAGNOSIS• Detect malfunction of CAN communication.• Judge as NG when data received from the combination meter is not normal.2. EXECUTION CONDITIONSecondary ParametersE ...