1. LATCH Check if the latch operates normally. If latch deformation, abnormal wear, or unsmooth lock operation is observed, replace the latch and actuator - rear gate. 2. ACTUATOR Unit inspection Preparation tool: Circuit tester 1. Check door lock operation Check the door lock operation when battery voltage is applied between the connectors.
2. Check switch Check the resistance between connector terminals.
3. If it does not operate properly as a result of inspection, replace the latch and actuator - rear gate. |
Removal
1. Remove the transmission assembly. Automatic Transmission Assembly > REMOVAL2. Remove the transmission case cover.3. Remove the air breather hose. Air Breather Hose > REMOVAL4. Remove the transmission hanger and transmission radio ground cord.5. Disconnect the harness connector from the turbine ...