Honda Civic manuals

Subaru Legacy Service Manual: Inspection

1. Check the motor operation when battery voltage is applied between the connector terminals.

LH side

Terminal No.

Inspection conditions

Standard

6 (+) — 3 (−)

Apply battery voltage between terminals.

Increase

3 (+) — 6 (−)

Apply battery voltage between terminals.

Decrease

RH side

Terminal No.

Inspection conditions

Standard

1 (+) — 4 (−)

Apply battery voltage between terminals.

Increase

4 (+) — 1 (−)

Apply battery voltage between terminals.

Decrease

2. If it does not operate properly as a result of inspection, replace the regulator and motor assembly - front.

Removal
1. Disconnect the ground terminal from the battery sensor, and wait for at least 60 seconds before starting work. NOTE2. Remove the trim panel - front door. Door Trim > REMOVAL3. Remove the sealing ...

Installation
1. Install the regulator and motor assembly - front.Tightening torque:7.5 N·m (0.8 kgf-m, 5.5 ft-lb)2. Install the glass assembly - front door. Front Door Glass > INSTALLATION3. Install the se ...

Other materials:

Installation
1. Install the leak check valve assembly to the canister.Tightening torque:8 N·m (0.8 kgf-m, 5.9 ft-lb)2. Connect the drain tube (A).CAUTION:• Check that there is no damage or dust on the quick connector. If necessary, clean the seal surface of the pipe.• Make sure that the quick ...