CAUTION: Be sure to prevent water or oil from contacting the connector terminal of secondary speed sensor. If adhesion occurs, replace with a new part. 1. Install the secondary speed sensor. NOTE: • Use new O-rings. • Apply CVTF to the O-rings. Tightening torque: 5 N·m (0.5 kgf-m, 3.7 ft-lb) 2. Connect the harness connector. 3. Install the transmission cover. Tightening torque: 8 N·m (0.8 kgf-m, 5.9 ft-lb) 4. Install the transmission assembly. Automatic Transmission Assembly > INSTALLATION |
InspectionDtc u0073 control module communication bus off
NOTE:For the diagnostic procedure, refer to LAN section. Basic Diagnostic Procedure1. OUTLINE OF DIAGNOSISDetect malfunction of CAN communication.Judge as NG when CAN communication failure has occurred.2. COMPONENT DESCRIPTION(Common Specifications)CAN Protocol 2.0 B (Active)Frame Format: 11 Bit ID ...