Honda Civic manuals

Subaru Legacy BN/BS (2015-2019) Service Manual: Installation

1. Install the manifold absolute pressure sensor to the intake manifold assembly, and connect the connector to the manifold absolute pressure sensor.

NOTE:

Use new O-rings.

Tightening torque:

3.4 N·m (0.3 kgf-m, 2.5 ft-lb)

2. Connect the ground terminal to battery sensor. NOTE

Inspection
1. Check that the manifold absolute pressure sensor has no deformation, cracks or other damages.2. Connect dry-cell battery positive terminal to terminal No. 3 and dry-cell battery ground terminal to ...

Mass air flow and intake air temperature sensor
...

Other materials:

Installation
1. Fabricate the cartridge nozzle tip as shown and set the sealant gun with the adhesive.(a)10 mm (0.39 in)(b)8 mm (0.31 in)(c)Sealant gun2. Smoothen and clean the adhesive surfaces of the glass - rear quarter and body using the same procedures as for the glass - front window. Windshield Glass > IN ...