Honda Civic manuals

Subaru Legacy BN/BS (2015-2019) Service Manual: Inspection

1. Measure the resistance between connector terminals.

Preparation tool: Circuit tester

Terminal No.

Inspection conditions

Standard

4 — 2

Always

Approx. 0.44 -

4 — 3

Approx. 1.12 -

4 — 1

Approx. 2.92 -

2. Replace the blower resistor if the inspection result is not within the standard value.

Removal
1. Disconnect the ground terminal from battery sensor. NOTE2. Release the hook, and remove the under cover assembly - passenger.3. Remove the blower resistor.(1) Disconnect the connector.(2) Remove t ...

Installation
1. Install the blower resistor.2. Install the under cover assembly - passenger.3. Connect the ground terminal to battery sensor. NOTE ...

Other materials:

Dtc b14a1 sunload sensor circuit low/open
DTC DETECTING CONDITION:Open circuit in the sunload sensor is detected for 3 seconds or more. (Displayed for current malfunction)NOTE:When the sunload sensor check is performed indoors or in the shade, it could be diagnosed as having an open circuit. Always check the sunload sensor in direct sunligh ...