CAUTION: • Be sure to prevent water or oil from contacting the connector terminal of secondary pressure sensor. If adhesion occurs, replace with a new part. • After installing the secondary pressure sensor, adjust the CVTF level. 1. Install the secondary pressure sensor. NOTE: • Use new O-rings. Tightening torque: 39 N·m (4.0 kgf-m, 28.8 ft-lb) 2. Connect the harness connector. 3. Lower the vehicle. 4. Connect the ground terminal to battery sensor. NOTE Tightening torque: 39 N·m (4.0 kgf-m, 28.8 ft-lb) |
InspectionBasic diagnostic procedure procedure
CAUTION:• The power steering control module continues to operate after the engine stops and calculate the temperature in the control module. Therefore, before starting service of the power steering system which requires disconnection of the connector, stop the engine and allow approx. 30 minut ...